Requirement to Correct Errors in Manifest Data Submitted to EPA
On this page:
- What Requires a Manifest
- What Requires Submission to the e-Manifest System
- Who Submits the Manifest
- Exemptions
- How to Correct the Data
What Requires a Manifest
EPA requires a manifest for off-site shipments bearing:
- Federally-regulated hazardous waste.
- State-regulated hazardous waste (origin or destination state).
- Toxic Substances Control Act-regulated polychlorinated biphenyls:
- Exported* or imported hazardous waste:
- Waste shipments transported as hazardous that are tested at arrival, regardless of outcome.
*Export manifests must be submitted to e-Manifest beginning December 1, 2025.
What Requires Submission to the e-Manifest System
You must enter all shipments that are required to use a manifest (listed above) into e-Manifest.
Export shipments must be submitted to e-Manifest beginning December 1, 2025.
Who Submits the Manifest
If using the paper workflows, the designated facility or approved alternate facility uploads the manifests to the e-Manifest system and certifies it. The generator and transporter do not submit copies to e-Manifest, even in the case of rejected loads.
Any party to the manifest can create manifests using the electronic workflows, but the designated facilities or approved alternate facilities must certify the manifests after the conclusion of the shipments.
Exemptions
Waste shipments originating with very small quantity generators are generally exempt from using a hazardous waste manifest, unless:
- The origin or destination state requires the use of a manifest by VSQGs.
- The waste is from a generator’s episodic event.
- The waste volume constitutes a generator’s change in category.
- The waste contains TSCA-regulated PCBs.
- The generator or designated facility is required to use a manifest by enforcement settlement or other supervision.
How to Correct the Data
Any party to the manifest with appropriate RCRAInfo access can correct a manifest after the final facility receives and certifies it. Consult the RCRAInfo Help Documentation for detailed instructions or the following videos:
Per requirements established in the Third Rule, waste handlers are obligated to make corrections to manifests within 30 days of regulators requesting corrections. EPA encourages waste handlers to designate facility contacts for manifest corrections through the site notification process.
The table below details which handlers are responsible for correcting each field of the manifest:
Box Number on the 8700-22 Manifest | Box Number on the 8700-22A Continuation Sheet | Field Information | Completion Responsibility | Correction Responsibility | Reasoning | Standard |
---|---|---|---|---|---|---|
1 | 21 | Generator ID Number | Generator | Designated Facility | Without a correct generator ID, the generator cannot access the manifest record. The designated facility who uploaded the manifest shall be responsible to correct it. | If the generator has an ID at the time the manifest is prepared, it must be used. The generator ID must be accurate. If a generator receives an ID after the manifest has been uploaded the designated facility must update any affected manifests upon state, EPA, or generator request. |
2 | 22 | Page Number | Generator | N/A | This information is not tracked in e-Manifest | N/A |
3 | N/A | Emergency Response Phone | Generator | Generator | The generator can provide detailed information about the hazardous waste and is responsible for providing emergency response details | This information must be correct as of the shipment date. |
4 | 23 | Manifest Tracking Number | Generator | EPA following valid request by industry | This field cannot be changed by industry to maintain data integrity | This information must accurately reflect what is printed on the manifest. Duplicate printings of the manifest tracking number shall be resolved in consultation with EPA. |
5 | 24 | Generator’s Name, Addresses, and Phone Number | Generator | Generator | The generator has the most up-to-date contact information for their facility | This information must be correct as of the shipment date. |
5 | N/A | Mailing Address (or Importer’s Address if import manifest) | Generator / Importer | Generator / Importer | The generator or importer has the most up-to-date contact information for their facility | This information must be correct as of the shipment date. |
5 | N/A | Site Address (if different) | Generator | Generator | The generator has the most up-to-date contact information for their facility | This information must be correct as of the shipment date. |
5 | N/A | Phone Number | Generator | Generator | The generator has the most up-to-date contact information for their facility | This information must be correct as of the shipment date. |
6 | N/A | Transporter 1 Company Name and EPA ID Number | Generator | Generator | Without a correct transporter ID, the transporter cannot access the manifest record. The generator who prepared the manifest shall be responsible to correct it. | This information must be correct as of the shipment date. |
7 | N/A | Transporter 2 Company Name and EPA ID Number | Generator | Generator | Without a correct transporter ID, the transporter cannot access the manifest record. The generator who prepared the manifest shall be responsible to correct it. | This information must be correct as of the shipment date. |
N/A | 25, 26 | Transporter [_] Company Name and EPA ID Number | Generator | Generator | Without a correct transporter ID, the transporter cannot access the manifest record. The generator who prepared the manifest shall be responsible to correct it. | This information must be correct as of the shipment date. |
N/A | N/A | Broker Flag | Broker | Generator | Without this flag being set to Yes, the broker ID cannot be entered and the broker cannot access the manifest record. The generator who contracted with the broker shall be responsible to correct it. | If the generator has an ID at the time the manifest is prepared, it must be used. The generator ID must be accurate. If a generator receives an ID after the manifest has been uploaded the designated facility must update any affected manifests upon state, EPA, or generator request. |
N/A | N/A | Broker ID Number | Broker | Generator | Without a correct broker ID, the broker cannot access the manifest record. The generator who contracted with the broker shall be responsible to correct it. | If the generator has an ID at the time the manifest is prepared, it must be used. The generator ID must be accurate. If a generator receives an ID after the manifest has been uploaded the designated facility must update any affected manifests upon state, EPA, or generator request. |
N/A | N/A | Broker Contact Name, Phone Number, and Email | Broker | Generator | The generator has the most up-to-date contact information for their broker | This information must be correct as of the shipment date. |
N/A | N/A | Contact Name (First, Last, Middle Initial) | Broker | Generator | The generator has the most up-to-date contact information for their broker | This information must be correct as of the shipment date. |
N/A | N/A | Contact Phone Number | Broker | Generator | The generator has the most up-to-date contact information for their broker | This information must be correct as of the shipment date. |
N/A | N/A | Contact Email Address | Broker | Generator | The generator has the most up-to-date contact information for their broker | This information must be correct as of the shipment date. |
8 | N/A | Designated Facility Details | Generator | Generator / Designated Facility / Alternate Facility / EPA | There are multiple responsible parties | This information must be correct as of the shipment date. |
8 | N/A | Name | Generator | EPA following valid request by industry, or Designated / Alternate Facility in case of rejection/residue | This field cannot be changed by industry for billing and regulatory reasons except in cases of rejection/residue | This information must be correct as of the shipment date. |
8 | N/A | Site Address | Generator | EPA following valid request by industry, or Designated / Alternate Facility in case of rejection/residue | This field cannot be changed by industry for billing and regulatory reasons except in cases of rejection/residue | This information must be correct as of the shipment date. |
8 | N/A | EPA ID Number | Generator | EPA following valid request by industry, or Designated / Alternate Facility in case of rejection/residue | This field cannot be changed by industry for billing and regulatory reasons except in cases of rejection/residue | This information must be correct as of the shipment date. |
8 | N/A | Phone Number | Generator | Designated Facility | The designated facility has the most up-to-date contact information for their facility | This information must be correct as of the shipment date. |
9-13 | 27-31 | Waste Information | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | Multiple standards apply. |
9 | 27 | Waste Line Number | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
9 | 27 | EPA Hazardous Waste flag | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
9 | 27 | US DOT Hazardous Materials flag | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
9 | 27 | US DOT Description (including Proper Shipping Name, Hazard Class, ID Number, and Packing Group (if any)) | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
10 | 28 | Container Details | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
10 | 28 | Number of Containers | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
10 | 28 | Type of Containers | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
11 | 29 | Total Quantity | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
12 | 30 | Unit Weight or Volume | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
13 | 31 | Waste Codes | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If differences from the manifest meet the discrepancy regulation requirements, the discrepancy section must be completed. |
14 | 32 | Special Handling Instructions and Additional Information | Generator | Generator / Transporter / Designated Facility | There are multiple responsible parties | Multiple standards apply. |
14 | 32 | Special Handling Instructions | Generator | Generator / Designated Facility | The handler that provided the initially provided information shall correct it | This information must include anything written on the paper manifest form and may include additional details. |
14 | 32 | Reference Information (e.g. Waste Profile, Other Custom Fields) | Generator | Generator / Designated Facility | The handler that provided the initially provided information shall correct it | This information must include anything written on the paper manifest form and may include additional details. |
14 | 32 | PCB Load Type | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Weight in Kilograms | Generator | Designated Facility | The designated facility has possession of the waste for further testing and measurement | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Earliest Date of Removal From Service | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Article or Container - Unique Identifier | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Article or Container - Type of Waste | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Bulk Waste - Identity of Waste | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB High or Low Voltage Capacitor - Unique Identifier | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Other - Type of Waste | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Transformer - Serial Number - Unique Identifier | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
14 | 32 | PCB Alternate Facility | Generator | Generator | The generator prepared this waste for disposal | This information must accurately reflect the waste. If the supporting documentation is inaccurate, a note explaining this change must be entered in Box 14. |
15 | N/A | Generator's or Offeror's Certification | Generator / Importer | Generator / Offeror / Importer | The generator / importer has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
15 | N/A | Generator's or Offeror's Printed or Typed Name | Generator / Importer | Generator / Importer | The generator / importer has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
15 | N/A | Generator's or Offeror's Signature | Generator / Importer | Generator / Importer | The generator / importer has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
15 | N/A | Signature Date (Month/Day/Year) | Generator / Importer | Generator / Importer | The generator / importer has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 33 | International Shipment Details | Importer / Exporter | Importer / Transporter / Exporter | The importer /exporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 33 | Import or Export Checkboxes | Importer / Exporter | Importer / Exporter | The importer /exporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 33 | Port of Entry or Exit | Importer / Exporter | Importer / Exporter | The importer /exporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 33 | Transporter Signature (for exports) | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 33 | Date Leaving U.S. | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 33 | International Consent Number | Designated Facility / Exporter | Designated Facility / Exporter | The designated facility / exporter has regulatory obligation to provide this information | This information must accurately reflect the facility's consent for that waste. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | 34, 35 | Transporter Acknowledgment of Receipt of Materials | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | N/A | Transporter 1 Printed or Typed Name | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | N/A | Transporter 1 Signature | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | N/A | Transporter 1 Signature Date (Month/Day/Year) | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | N/A | Transporter 2 Printed or Typed Name | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | N/A | Transporter 2 Signature | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
17 | N/A | Transporter 2 Signature Date (Month/Day/Year) | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 34, 35 | Transporter [_] Printed or Typed Name | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 34, 35 | Transporter [_] Signature | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
N/A | 34, 35 | Transporter [_] Signature Date (Month/Day/Year) | Transporter | Transporter | The transporter has regulatory obligation to provide this information | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
18 | 36 | Discrepancy Details | Designated Facility | Designated Facility | The designated facility has regulatory obligation to determine discrepancies | Multiple standards apply. |
18a | 36 | Discrepancy Type Indication Space | Designated Facility | Designated Facility | The designated facility has regulatory obligation to determine discrepancies | This information must match the actual discrepancy identified by the designated or alternate facility. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
18a | 36 | Manifest Reference Number | Designated Facility | Designated Facility | The designated facility creates the new manifest and thus selects the manifest number used | This information must match the actual rejection manifest number. |
18b | 36 | Alternate Facility (or Generator) Details | Alternate Facility / Generator | Alternate Facility / Generator / EPA | There are multiple responsible parties | This information must be correct as of the shipment date. |
18b | 36 | Alternate Facility (or Generator) Name | Alternate Facility / Generator | EPA following valid request by industry | This field cannot be changed by industry for billing and regulatory reasons | This information must be correct as of the shipment date. |
18b | 36 | Alternate Facility (or Generator) EPA ID Number | Alternate Facility / Generator | EPA following valid request by industry | This field cannot be changed by industry for billing and regulatory reasons | This information must be correct as of the shipment date. |
18b | 36 | Alternate Facility (or Generator) Phone Number | Alternate Facility / Generator | Alternate Facility / Generator | The alternate facility has the most up-to-date contact information for their facility | This information must be correct as of the shipment date. |
18c | 36 | Alternate Facility (or Generator) Signature Details | Alternate Facility / Generator | Alternate Facility / Generator | The alternate facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
18c | 36 | Alternate Facility (or Generator) Signature | Alternate Facility / Generator | Alternate Facility / Generator | The alternate facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
18c | 36 | Alternate Facility (or Generator) Signature Date (Month/Day/Year) | Alternate Facility / Generator | Alternate Facility / Generator | The alternate facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
19 | 37 | Hazardous Waste Report Management Method Codes | Designated or Alternate Facility | Designated or Alternate Facility | The designated or alternate facility managed this waste and must attest to how this was done | This information must accurately reflect what happened to the waste. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
20 | N/A | Designated Facility Certification of Receipt | Designated Facility | Designated Facility | The designated facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
20 | N/A | Designated Facility Printed or Typed Name | Designated Facility | Designated Facility | The designated facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
20 | N/A | Designated Facility Signature | Designated Facility | Designated Facility | The designated facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
20 | N/A | Designated Facility Signature Date (Month/Day/Year) | Designated Facility | Designated Facility | The designated facility completed this section | This information must match the paper manifest form. If the paper manifest is inaccurate, a note explaining this change must be entered in Box 14. |
Other | Other | Paper Manifest Attachment | Designated or Alternate Facility | Designated or Alternate Facility | The designated or alternate facility has physical possession of the final manifest | A scan of the paper manifest bearing any corrections must be uploaded if requested by EPA or state regulators. |